Tripp Lite 650VA 360W Line-Interactive Tower UPS
- Correct brownouts as low as 170V and overvoltages as high as 280V without using battery
- 650VA capacity supports a variety of desktop and networking devices
- Fused C14 inlet accepts user-supplied AC power cord with country-specific plug
- Ultra-compact design saves space
INPUT
Rated input current (Maximum Load) | 2.8A |
Nominal Input Voltage(s) Supported | 230V AC |
UPS Input Connection Type | C14 inlet |
UPS Input Connection Description | The C14 inlet accepts included or user-supplied AC power cords |
Input Phase | Single-Phase |
OUTPUT
Output Volt Amp Capacity (VA) | 650 |
Output Watt Capacity (Watts) | 360 |
Nominal Voltage Details | 230V nominal output in battery mode |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Automatic frequency selection |
Output Voltage Regulation (Line Mode) | 230V (±9.5%) |
Output Voltage Regulation (Battery Mode) | ±10% |
Included Output Power Cables | Includes 2 C13 to C14 power cables |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
Output Receptacles | (4) C13 |
Individually Controllable Load Banks | No |
BATTERY
Battery Type | Valve Regulated Lead Acid (VRLA) |
Half Load Runtime (min.) | 6 min. (180w) |
Expandable Runtime | No |
DC System Voltage (VDC) | 12 |
Battery Recharge Rate (Included Batteries) | 8 hours from 10% to 90% |
Battery Replacement Description | See manual for battery replacement information |
VOLTAGE REGULATION
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 170 and as high as 280 |
Overvoltage Correction | Input voltages between 253 and 280 are reduced by 15% |
Undervoltage Correction | Input voltages between 170 and 207 are boosted by 18% |
USER INTERFACE, ALERTS & CONTROLS
Switches | 1 Switch controls off/on power status |
Audible Alarm | Audible alarm with distinct tone patterns indicates low-battery, overload, replace-battery and fault-mode |
LED Indicators | 3 front panel LEDs indicate off/on power status, line power availability, battery mode operation, overload, replace-battery and fault-mode |
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating | 312 |
UPS AC Suppression Response Time | Instantaneous |
EMI / RFI AC Noise Suppression | Yes |
PHYSICAL
Installation Form Factors Supported with Included Accessories | Tower |
Primary Form Factor | Tower |
Primary UPS Depth (mm) | 300 |
Primary UPS Height (mm) | 142 |
Primary UPS Width (mm) | 102 |
Shipping Weight (kg) | 5.08 |
UPS Housing Material | PVC |
UPS Power Module Weight (kg) | 4.81 |
ENVIRONMENTAL
Operating Temperature Range | 0 to 40°C |
Storage Temperature Range | -15 to 45°C |
Relative Humidity | Up to 90%, non-condensing |
AC Mode BTU / Hr. (Full Load) | 26 |
AC Mode Efficiency Rating (100% Load) | 95% |
Operating Elevation (m) | 0-2000m |
COMMUNICATIONS
Communications Interface | None |
LINE / BATTERY TRANSFER
Transfer Time | 6 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) | 170 |
High Voltage Transfer to Battery Power (Setpoint) | 280 |
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) | Yes |
High Availability UPS Features | Automatic Voltage Regulation (AVR); Surge/noise protection |
STANDARDS & COMPLIANCE
UPS Certifications | CE |
Certification Details | IEC 62040-1:2008+A1:2013; EN62040-2, 2006, C2 |
Reviews