APC Smart-UPS SRT 10000VA 230V (SRTG10KXLI) details
Output
Max Configurable Power (Watts)10.0kWatts / 10.0kVA
Output Voltage DistortionLess than 2 %
Output Frequency (sync to mains)50/60 Hz +/- 3 Hz Sync to mains
Other Output Voltages220 V, 240 V
Load Crest Factor3 : 1
Topology Double conversion online
Waveform type Sine wave
Bypass Internal bypass (automatic and manual)
Input
Input frequency40 – 70 Hz Auto-sensing
Input voltage range for main operations100 – 275 Adjustable (half load), 160 – 275, 173 – 476 Adjustable (half load)V
Other Input Voltages220 V, 240 V, 380 V, 415 V
Batteries & Runtime
Battery type Lead-acid battery
Typical recharge time1.5hour(s)
Nominal Battery Voltage+/- 192 V (split battery referenced to neutral)
Replacement BatteryAPCRBC140
Expected Battery Life (years)3 – 5
RBC Quantity2
Battery Charge Power (Watts)1.195kWatts
Extendable Run Time1
Extended Run OptionsAPC-Smart-UPS-SRT-10000VA-230V
Runtime View Runtime Graph
View Runtime Chart
Efficiency View Efficiency Graph
Communications & Management
Interface Port(s)RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB
Control panel Multifunction LCD status and control console
Audible Alarm Audible and visible alarms prioritized by severity
Emergency Power Off (EPO)Yes
Available SmartSlot™ Interface Quantity1
Surge Protection and Filtering
Surge energy rating480Joules
Smart-UPS On-Line Features & Benefits
Serviceability
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predictive failure notification.Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification Warns when a battery is not available to provide backup power.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms Provides notification of changing utility power and UPS power conditions
Protection
Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Cold-start capable Provides temporary battery power when the utility power is out.
Input Power Factor Correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Marketing features
Save time with easy and convenient remote/network accessibility.Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Low operating and maintenance costs with proven reliability and intelligent battery management .Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Avoids costly power problems by keeping your IT equipment and data protected and available .Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Manageability
InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
SmartSlot Customize UPS capabilities with management cards.
Serial connectivity Provides management of the UPS via a serial port.
LED status indicators Quickly understand unit and power status with visual indicators.
Network manageable Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Adaptability
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.
Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.
Availability
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Scalable runtime Allows additional run time to be quickly added as needed.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Reviews